Vortex PhD™ In-Line Vortex Flow Meter
»Features »Specifications »Installation »Model Codes
 
EMCO's model Vortex PhD® is an in-line vortex shedding flow meter capable of measuring liquids or gases, including steam, for pipe sizes from 1" to 12", available in stainless steel and carbon steel. The PhD flow meter has no moving parts, rugged construction, and microprocessor-based electronics for high accuracy in many flow metering applications. The Vortex PhD flow meter, with no moving parts, provides accurate measurement with lower maintenance, and lower total cost of ownership than other flow meter technologies.
    
»View Demo
»Documentation
Vortex PhD
»Technology
Features
Accuracy
  • ± 0.7% of rate accuracy for liquids
  • ± 1.0% of rate accuracy for gas and steam
  • ± 0.15% of rate repeatability
  • Advanced digital filtering scheme used by the microprocessor ensures accurate and reliable flow measurement and control
  • Calibration is traceable to NIST
Reliability & Safety
  • No moving parts or holes that can clog
  • No internal gaskets that could fail and cause hazardous leaks
  • The industry's first fully-welded sensor construction
  • Sensor can be removed under full-flow conditions without process shutdown or risk of exposure to hazardous fluids
  • No need for bypass piping installation
  • FM, CSA, and CENELEC approvals
Ease of Operation
  • Factory calibrated and programmed for specific applications
  • Setup and use without any additional calibration or programming
  • The local display alternates between flow rate and totalized flow
  • Menu-driven EZ-Logic™ user interface enables local programming
  • HART® protocol communication

Back to top

Specifications
Performance Specifications
Accuracy
(linear ranges)
Liquid ± 0.7% of flow rate
Gas/Steam ± 1.0% of flow rate
Repeatability ± 0.15% of flow rate
Response time Adjustable from 1 to 100 sec (analog output version)

Back to top

Operating Specifications
Fluid types Liquid, gas, or steam
Measurable flow velocities Liquid 1.5 to 32 ft/sec (0.5 to 9 m/s)
Gas/Steam to 300 ft/sec ( to 91 m/s) (p=density lb/ft³ (kg/m³)
Process pressure According to flange specifications, up to ANSI class 600
Process temperature limit – 40 to 750°F (– 40 to 400°C)
Ambient temperature limit Standard – 20 to 140°F (– 29 to 60°C)
With Local Display 32 to 140 °F (0 to 60 °C)
Ambient humidity limit Up to 100% RH non-condensing
Power requirements Standard 18 to 40 VDC
Option 110/220 VAC, 50/60 Hz
Output signals Scalable 4 to 20 mA current and scalable frequency/pulse 0 to10 kHz HART® communications protocol

Back to top

Physical Specifications
Materials Wetted parts Stainless steel, or carbon steel
All other Parts Stainless steel
Electronics enclosure Coated 383 AL (corrosion-resistant epoxy paint) NEMA 4X
Process connection ANSI B16.5 class 150, 300, or 600 DIN 2501, PN16, PN40, PN64
Transmitter Standard Single transmitter, single sensor
Mounting Standard Transmitter integrally mounted on sensor
Option Transmitter remote mounted
Display Standard No display
Option Local indicator alternately displays flow rate and totalized flow in user-selectable, engineering units. It is a 2-line, 8-character per line, LCD display.
Approvals FM Explosion proof for Class I, Division 1, Groups B, C, & D Class II, Division 1, Groups E, F, & G Class I, Division 2, Groups A, B, C, & D Class II, III, Division 2, Groups F & G
CSA Explosion proof for Class I, Division 1, Groups B, C, & D Class II, Division 1, Groups E, F, & G Class III
Certified by DEMKO for use in potentially explosive atmosphere Eex d [ib] IIC T6 (flame proof enclosure and intrinsic safety).

Back to top

Installation
Installation Specifications
Mounting Install flow meter vertically, horizontally, or at any angle. For liquid service, the flow line must be full during flow meter operation; in vertical lines, flow direction should be upward for optimum flow meter performance.
Straight run piping (D = internal diameter of pipe) Upstream Downstream
One 90° elbow before meter 10 D 5 D
Two 90° elbows before meter 15 D 5 D
Two 90° elbows out of plane before the meter
30 D
5 D
Reduction before the meter 10 D 5 D
Regulator or valve partially closed before the meter
30 D
5 D
Pressure and temperature taps Mount pressure tap 3.5 to 7 pipe diameters downstream of the flow meter. Mount temperature tap an additional 3.5 to 7 pipe diameters downstream of the pressure tap.
Site selection Select installation location to minimize turbulence and swirl. The piping configuration, i.e., valves, elbows, pumps, may add disturbances to the flow.
Serviceability The sensor element can be removed, and replaced, without removing the flow meter body from the process line and without process shutdown for process pressures below 750 psig (52 barg).

Back to top

Model Codes
Model Codes
Category Description Suffix Codes
Wetted parts Wetted parts stainless steel (sizes 1 to 12") PhD-90 - - - - - -
Carbon steel (sizes 6 to 12") PhD-92 - - - - - -
Fluid type Steam or gas - S - - - - -
Liquid - L - - - - -
Line size 1" - - 10 - - - -
1.5" - - 15 - - - -
2" - - 20 - - - -
3" - - 30 - - - -
4" - - 40 - - - -
6" - - 60 - - - -
8" - - 80 - - - -
10" - - 100 - - - -
12" - - 120 - - - -
25 mm - - DN25 - - - -
40 mm - - DN40 - - - -
50 mm - - DN50 - - - -
80 mm - - DN80 - - - -
100 mm - - DN100 - - - -
150 mm - - DN150 - - - -
200 mm - - DN200 - - - -
250 mm - - DN250 - - - -
300 mm - - DN300 - - - -
Connection type Wafer1 - - - W - - -
Flange - - - F - - -
Connection rating
ANSI Class 150
- - - - 150 - -
ANSI Class 300
- - - - 300 - -
ANSI Class 600 - - - - 600 - -
DIN, PN 16 - - - - PN16 - -
DIN, PN 40 - - - - PN40 - -
DIN, PN 64
- - - - PN64 - -
Options No indicator/totalizer option2 - - - - - STD -
FM Approved3
- - - - - FM -
CSA Approved
- - - - - CSA -
CENELEC Approved3 - - - - - CEN -
Local indicator & totalizer4 - - - - - LOC-
TOT
-
Remote Mount Electronics5 - - - - - RMT -
Integral 110 VAC Input6 - - - - - 110 -
Integral 220 VAC Input6 - - - - - 220 -
Internal sensor wires
Teflon, -40° to 400° F (-40° to 204° C) - - - - - - T
Fiberglass, 150° to 750° F (65° to 400° C)
- - - - - - F

PhD-90-S-60-F-300-LOC-TOT-RMT-T represents a 6" in-line vortex flow meter with stainless steel wetted parts, for steam or gas applications, with ANSI class 300 flanged connection, a local indicator and totalizer, with remote-mounted transmitter, and teflon sensor wires.

Notes:

  1. Wafer-style meters available in stainless steel (sizes 1 to 4" only).
  2. Has 4 to 20 mA and/or 50% duty cycle frequency output. A 50% duty cycle frequency can be scaled.
  3. FM and CENELEC approved meters come with a magnet wand. For all other meters the wand can be ordered as an option.
  4. At least one local indicator is recommended at each site. If one display will be used on many meters, display boards should be purchased separately.
  5. Remote-mount electronics are required for high process temperatures (refer to the general specification). The standard remote-mount option comes with 30' of cable.
  6. Not available with European CE Mark or FM, CSA and CENELEC approvals.
Back to top