Temperature Transmitter
»Features »Specifications »Installation »Model Codes
 
    
»Documentation
Tempature Transmitter
»Technology
EMCO's TEM platinum resistance temperature sensors measure process fluid temperature for most applications. The TEM transmitter uses a resistance temperature device (RTD) to measure process temperature. RTDs operate on the principle that the resistance of the sensing device is proportional to the temperature, producing a highly repeatable and exceptionally stable resistance versus temperature relationship.

The TEM transmitter may be selected with either a direct RTD output or with an industry standard 4 to 20 mA current output. The current output includes a preamplifier that is factory scaled and calibrated to one of several standard temperature ranges in either Fahrenheit or Celsius.

The TEM is a thermowell mounted to allow installation and removal without process shutdown. Several immersion lengths are available to accommodate a wide range of pipe sizes.

Features
  • RTD or 4 to 20mA current output (linear)
  • Factory calibrated over selected range
  • Rugged design
  • Thermowell included

Back to top

Specifications
Performance Specifications
Accuracy (ice point) RTD sensor ±0.12% (1000 ±1.2 Ω)
Interchangeability Accuracy ±0.9°F or 0.8% (±0.5°C)
Stability Better than ±0.45°F (±0.25°C) per year
Sensing element coefficient 0.00385 Ω/Ω/°C
Ambient temperature effect Zero 0.03 + 0.005% of span per °C
Span 0.02 + 0.003% of span per °C

Back to top

Operating Specifications
Temperature ranges RTD -40 to 800°F (-40 to 426°C)
Transmitter 10 models ranging from -40 to 500°F (-40 to 260°C)
Ambient temperature limit -30 to 160°F (-34 to 71°C)
Storage temperature limit -6 to 185°F (-51 to 85°C)
Ambient humidity limit 0 to 100% relative humidity
Thermowell pressure limit 3500 psig (241 barg) at 1140°F (615°C)
RTD sensor Output 3-wire RTD
Current 1 mA recommended, 2 mA max
Insulation resistance 100 mΩ min at 300 VDC at 75 °F
Optional preamplifier Output 4 to 20 mA, 2-wire
Power supply 24 VDC nominal, operable from 12 to 40 VDC
Load resistance 600 Ω at 24 VDC, dependent on supply voltage

Back to top

Physical Specifications
Materials Sensing element 1000 Ω thin-film platinum
RTD sheath 316 stainless steel
Junction box Aluminum
Thermowell 316 stainless steel
Process connection (Thermowell) 1/2" NPT
Electrical connection Junction box with terminal block for external wiring, 3/4" NPT female connection for conduit
Weight 3 lb (1.4 kg)

Back to top

Installation
For installation information, contact your local EMCO representative or the factory.
Back to top


Model Codes
Model Codes
Category Description Suffix Codes
Model Precision RTD with thermowell TEM-30 - - -
Preamplifier (termperature range) none (RTD only) - RTD - -
Preamplifier scaled from 32 to 68°F (liquid or gas) - T09 - -
Preamplifier scaled from 0 to 250°F (liquid or gas) - T10 - -
Preamplifier scaled from -40 to 150°F (liquid or gas) - T11 - -
Preamplifier scaled from 212 to 450°F (liquid or gas) - T12 - -
Preamplifier scaled from 212 to 500°F (steam) - T14 - -
Preamplifier scaled from 212 to 900°F (steam) - T13 - -
Preamplifier scaled from -17.7 to 121.1°C (liquid or gas) - T20 - -
Preamplifier scaled from -40 to 60°C (liquid or gas) - T21 - -
Preamplifier scaled from 100 to 204°C (steam) - T22 - -
Preamplifier scaled from 100 to 260°C (steam) - T24 - -
Preamplifier scaled from 100 to 426°C (steam) - T23 - -
Transmitter can be scaled to accommodate special requests and bar scaling - TXX - -
Thermowell length 2" Thermowell length - - 2 -
3" Thermowell length - - 3 -
4" Thermowell length - - 4 -
6" Thermowell length - - 6 -
8" Thermowell length - - 8 -
10" Thermowell length - - 10 -
12" Thermowell length - - 12 -
RTD wires (internal) Teflon, -4 to 400°F (-40 to 204°C) - - - T
Fiberglass, 150 to 800°F (65to 427°C) - - - F

TEM-30-T13-6-F represents a RTD, the preamplifier is for steam and has a temperature range of 212 to 900°F, the 6” Thermowell has fiberglass wiring.