EMCO left column
Home
Who Is EMCO
Technologies
Fluids
Markets
EMCO Products
Documentation
Sizing Program
News/Events
Contact Us
Contact Us
Free Flow Evaluation
Header Header
»Vortex PhD
(In-Line Vortex)
»V-Bar
(Insertion Vortex)
»Sono-Trak Transit Time
(Ultrasonic)
»UniMag®
(Electromagnetic)
»Temperature Transmitter
»Pressure Transmitter

»Hydro-Flow
(Water Vortex)

»Turbo-Bar
(Insertion Turbine)
»Sono-Trak Doppler
(Ultrasonic)
»Flow Processors »MAGFLO®
(Electromagnetic)


Pressure Transmitter
»Features »Specifications »Installation »Model Codes
 
    
»Documentation
Pressure Transmitter
»Technology
The Model PT combines micro-machined silicon diaphragms with fully welded stainless steel pressure ports to provide a highly accurate, stable pressure transmitter. It is constructed with the materials and environmental protection required for industrial applications.

The silicon sensors incorporate developments derived from aerospace applications. These developments are used to decrease output noise, non-linearity, and hysteresis and to improve long-term stability.

A detachable industrial electrical connector provides access to independent zero and span controls.

Each transmitter incorporates RFI/EMC and electrical spike protection.






Features
  • Process pressure range: 1.5 to 1,000 psi (0.1 to 69 bar)
  • Accuracy of ± 0.25% of full scale
  • Process temperature range: -40 to 250 °F (-40 to 121°C)
  • 2-wire, 4 to 20 mA output
  • CE and FM approved
Back to top

Specifications
Performance Specifications
Accuracy The best straight line - determined from the combined effects of non-linearity, hysteresis, and repeatability ±0.25% of full scale
15 to 122°F (-9.4 to 50°C) 1.0% of full scale
-5 to 175°F (-20.6 to 79.4°C) 2.0% of full scale
Ambient Temperature Effect
15 to 122°F (-9.4 to 50°C) 2.0% full scale
-5 to 175°F (-20.6 to 79.4°C) 3.0% of full scale

Back to top

Operating Specifications
Service Liquid, gas, and steam
Operating Pressure Range 7 models from 0 to 1000 psig (0 to 69 barg)
Proof Pressure The rated pressure can be exceeded by 2X without degrading performance
Operating Temperature Range Ambient -40 to 175°F (-40 to 80°C)
Process media -40 to 250°F (-40 to 121°C)
Storage -40 to 250°F (-40 to 121°C)
Power Supply Requirements 9 to 30 VDC, across red wire (positive) and blue wire (negative). This voltage must appear across the transmitter terminals
Output Signals 4 to 20 mA (2-wire configuration) proportional for zero to full-scale pressure

Back to top

Physical Specifications
Materials of construction Isolated Diaphragm HastelloyC®-276
Tranducer Body 316 stainless steel
Process connection 1/4" NPT female
Calibration standards Transmitters are calibrated against precision presure calibration equipment traceable to NIST.
Weight 14 oz. nominal
Electrical connection Two 22 AWG wires

Back to top

Installation
For installation information, contact your local EMCO representative or the factory.
Back to top


Model Codes
Model Codes
Description Part Number
PT for pressure range 0 to 50 psig (0 to 3.44 barg) 011115-1
PT for pressure range 0 to 100 psig (0 to 6.89 barg) 011115-2
PT for pressure range 0 to 150 psig (0 to 10.34 barg) 011115-3
PT for pressure range 0 to 200 psig (0 to 13.79 barg) 011115-4
PT for pressure range 0 to 250 psig (0 to 17.24 barg) 011115-5
PT for pressure range 0 to 500 psig (0 to 34.47 barg) 011115-6
PT for pressure range 0 to 1000 psig (0 to 68.95 barg)3 011117-2
PT to accomodate special requests and bar scaling1 011117-1
Mounting kit (includes bleed valve, siphon tube, plug, nipple, and tee) must be used with PT if process temperature is above 250°F (121°C) 010589-4

  1. Determine the pressure range that is most appropriate for your application. Contact your EMCO representative for details.
  2. Specify the typical service conditions. A siphon tube on the PT is required for all applications above 250°F (121°C)
  3. Not FM approved.
Back to top

Site Map   |   Contact Us   |   Privacy
EMCO Flow Systems is a division of Spirax Sarco, Inc.
Copyright 2008. All rights reserved.